Abstract:
Commonly used analytical approaches for estimation of pumping-induced drawdown and stream depletion are based on a series of idealistic assumptions about the stream-aquifer system. A new solution has been developed for estimation of drawdown and stream depletion under conditions that are more representative of those in natural systems (finite width stream of shallow penetration adjoining an aquifer of limited lateral extent). This solution shows that the conventional assumption of a fully penetrating stream will lead to a significant overestimation of stream depletion (> 100%) in many practical applications. The degree of overestimation will depend on the value of the stream leakance parameter and the distance from the pumping well to the stream. Although leakance will increase with stream width, a very wide stream will not necessarily be well represented by a model of a fully penetrating stream. The impact of lateral boundaries depends upon the distance from the pumping well to the stream and the stream leakance parameter. In most cases, aquifer width must be on the order of hundreds of stream widths before the assumption of a laterally infinite aquifer is appropriate for stream-depletion calculations. An important assumption underlying this solution is that stream-channel penetration is negligible relative to aquifer thickness. However, an approximate extension to the case of nonnegligible penetration provides reasonable results for the range of relative penetrations found in most natural systems (up to 85%). Since this solution allows consideration of a much wider range of conditions than existing analytical approaches, it could prove to be a valuable new tool for water management design and water rights adjudication purposes.Keywords:
Drawdown (hydrology)
Sustainable groundwater management is founded on the sound understanding of the effects of water extraction on the aquifer water level and the springs and streams receiving groundwater discharge. Pumping test data are commonly used in extraction licence applications to evaluate aquifer properties and assess the magnitude of storage depletion resulting from pumping. However, a short duration (eg 48 hours) pumping test can fail to detect the presence of aquifer boundaries, as the cone of depression is not large enough to reach the boundaries. This may cause an underestimation of long-term drawdown and an overestimation of permissible extraction rate (ie safe yield). In the rural town of Irricana in Alberta, groundwater extraction licences for municipal water supply wells were issued in the early 1980s based on the analysis of 48-hour pumping tests. Actual water extraction rates were substantially below the licensed rates, but the unanticipated and excessive drawdown in the aquifer forced the town to discontinue pumping and switch to surface water supply after 25 years. To examine the cause of overallocation, a new 48-hour pumping test was conducted in the same aquifer, which included an extended drawdown analysis using 26 days of recovery data. Geological formation logs for existing wells in the area surrounding Irricana were used to infer the extent of sandstone aquifer units within the heterogeneous bedrock formation. The new data analysis showed that the aquifer is semi-closed, contrary to the infinite-aquifer assumption used in the original pumping test, which caused additional drawdown due to the aquifer boundary effects. This study suggests an improved procedure for estimation of storage depletion using standard hydrogeological methods and readily available data. The new procedure provides a useful tool as part of adaptive groundwater management, in which water levels and other relevant variables are monitored and licensed extraction rates are adjusted accordingly.
Drawdown (hydrology)
Cone of depression
Aquifer test
Water well
Groundwater discharge
Bedrock
Cite
Citations (0)
Abstract A quasi, a mixed, and a weighted three‐dimensional model are applied to approximate the three‐dimensional, unsteady drawdown in vertical pumping and observation wells, fully or partially penetrating a single, vertically heterogeneous, anisotropic aquifer. Cases of confined, semiconfined, and unconfined flow conditions are considered. Numerical examples are used to quantify the numerical error of the methods, introduced by the vertical heterogeneity of the aquifer. Results of pumping test data analysis in a three‐layer, anisotropic aquifer with multiple screens in the pumping well are presented.
Drawdown (hydrology)
Aquifer test
Cite
Citations (7)
The buried‐valley aquifers that are common in the glacial deposits of the northern hemisphere are a typical case of the strip aquifers that occur in many parts of the world. Pumping from a narrow strip aquifer leads to much greater drawdown and much more distant drawdown effects then would occur in a sheet aquifer with a similar transmissivity and storage coefficient. Widely used theories for radial flow to wells, such as the Theis equation, are not appropriate for narrow strip aquifers. Previously published theory for flow to wells in semiconfined strip aquifers is reviewed and a practical format of the type curves for pumping‐test analysis is described. The drawdown response of strip aquifers to pumping tests is distinctive, especially for observation wells near the pumped well. A case study is presented, based on extensive pumping test experience for the Estevan Valley Aquifer in southern Saskatchewan, Canada. Evaluation of groundwater resources in such buried‐valley aquifers needs to take into account the unusually large drawdowns in response to pumping.
Drawdown (hydrology)
Aquifer test
Aquifer properties
Water well
Surficial aquifer
Cone of depression
Slug test
Cite
Citations (47)
ABSTRACT A numerical simulation and analytical study of a constant‐rate pumping test, for a well situated at the centre of a disc of anomalous transmissivity and storage coefficient, have been used to aid in the interpretation of tests performed in a “patchy” aquifer in India. Equations describing the long‐time behaviour of drawdown show that Jacob's method can be employed to estimate the regional transmissivity from drawdowns measured at any point in the aquifer or in the pumping well. However, these equations also show that an average storage coefficient should be calculated from drawdowns measured outside the aquifer discontinuity. The results of this study support the hypothesis that the average transmissivity of a heterogeneous aquifer can be calculated from rates of drawdown observed after long periods of pumping.
Drawdown (hydrology)
Aquifer test
Discontinuity (linguistics)
Cone of depression
Aquifer properties
Cite
Citations (62)
Prediction of aquifer drawdown is necessary for the correct management of an aquifer. The use of mathematical models is one important tool to predict the status of an aquifer drawdown. In this study, we have used the MODFLOW model to simulate the SarzeRezvan Aquifer. After having proven an excellent match between the generated model and the aquifer's natural condition, we used this model to predict the aquifer drawdown. To simulate the change in water head under unsteady state, we used water head data from 2001-2010. The PEST computational code was used for calibration. Water head data from April to September 2011 has been used for verification. The Root Mean Square Error (RMSE) between observed and calculated (by the model) water head is 0.854, which indicates excellent agreement with the aquifer's natural condition. Therefore, this model was used to predict the aquifer drawdown. The results of the model prediction have shown that if pumping is going to be constant for 8 years, the drawdown will be approximately 10.56 m, after 8 years.
Drawdown (hydrology)
MODFLOW
Aquifer test
Piezometer
Hydraulic head
Groundwater model
Cite